    TeSys F Contactors
    -
    LC1F400F7
    Also available in 220Vac
    LC1F400M7(Just let us know which coil you need)
    Main
    range
    TeSys
    product name
    TeSys F
    product or component type
    Contactor
    device short name
    LC1F
    contactor application
    Motor control
    Resistive load
    utilisation category
    AC-1
    AC-3
    AC-4
    poles description
    3P
    power pole contact composition
    3 NO
    System Voltage
    <= 1000 V AC 50/60 Hz
    <= 460 V DC
    [Ie] rated operational current
    500 A (<= 104 °F (40 °C)) at <= 440 V AC AC-1
    400 A (<= 131 °F (55 °C)) at <= 440 V AC AC-3
    motor power kW
    75 kW at 400 V AC 50/60 Hz AC-4
    200 kW at 380...400 V AC 50/60 Hz AC-3
    220 kW at 415 V AC 50/60 Hz AC-3
    250 kW at 440 V AC 50/60 Hz AC-3
    257 kW at 500 V AC 50/60 Hz AC-3
    185 kW at 1000 V AC 50/60 Hz AC-3
    110 kW at 220...230 V AC 50/60 Hz AC-3
    280 kW at 660...690 V AC 50/60 Hz AC-3
    [Uc] control circuit voltage
    110 V AC 40...400 Hz
    Complementary
    [Uimp] rated impulse withstand voltage
    8 kV
    overvoltage category
    III
    [Ith] conventional free air thermal current
    500 A at <= 104 °F (40 °C)
    rated breaking capacity
    3200 A conforming to IEC 60947-4-1
    [Icw] rated short-time withstand current
    3600 A <= 104 °F (40 °C) 10 s
    2400 A <= 104 °F (40 °C) 30 s
    1700 A <= 104 °F (40 °C) 1 min
    1200 A <= 104 °F (40 °C) 3 min
    1000 A <= 104 °F (40 °C) 10 min
    associated fuse rating
    400 A aM at <= 440 V
    500 A gG at <= 440 V
    average impedance
    0.26 mOhm at 50 Hz - Ith 500 A
    [Ui] rated insulation voltage
    1000 V conforming to IEC 60947-4-1
    1500 V conforming to VDE 0110 group C
    power dissipation per pole
    42 W AC-3
    65 W AC-1
    mounting support
    Plate
    standards
    EN 60947-1
    EN 60947-4-1
    IEC 60947-1
    IEC 60947-4-1
    JIS C8201-4-1
    product certifications
    ABS
    BV
    CSA
    DNV
    LROS (Lloyds register of shipping)
    RINA
    RMRoS
    UL
    CB
    connections - terminals
    Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable end
    Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
    Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable end
    Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable end
    Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
    Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
    Power circuit: lugs-ring terminals 2 cable(s) 0.23 in² (150 mm²)
    Power circuit : bolted connection
    Power circuit : bar 2 x (30 x 5 mm)
    tightening torque
    Power circuit: 309.73 lbf.in (35 N.m)
    Control circuit: 10.62 lbf.in (1.2 N.m)
    control circuit voltage limits
    0.85...1.1 Uc at 131 °F (55 °C) operational 40...400 Hz
    0.3...0.5 Uc at 131 °F (55 °C) drop-out 40...400 Hz
    inrush power in VA
    1075 VA at 68 °F (20 °C) (cos ϕ 0.9) 40...400 Hz
    hold-in power consumption in VA
    15 VA at 68 °F (20 °C) (cos ϕ 0.9) 40...400 Hz
    heat dissipation
    14 W
    operating time
    100...170 ms opening
    40...65 ms closing
    mechanical durability
    10 Mcycles
    operating rate
    2400 cyc/h at <= 131 °F (55 °C)
    Environment
    IP degree of protection
    IP20 front face with shrouds (ordered separately) conforming to IEC 60529
    IP20 front face with shrouds (ordered separately) conforming to VDE 0106
    protective treatment
    TH
    ambient air temperature for operation
    23...131 °F (-5...55 °C)
    ambient air temperature for storage
    -76...176 °F (-60...80 °C)
    permissible ambient air temperature around the device
    -40...158 °F (-40...70 °C)
    operating altitude
    9842.52 ft (3000 m) without derating
    mechanical robustness
    Shocks resistance contactor closed 15 Gn for 11 ms
    Shocks resistance contactor open 6 Gn for 11 ms
    Vibrations resistance contactor closed 5 Gn, 5...300 Hz
    Vibrations resistance contactor open 1.5 Gn, 5...300 Hz